Alternative NSN: 5950-01-331-3908 |
Item Name: Transformer Pulse |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5950 Coils and Transformers |
NIIN: 013313908 |
NCB Code: USA (01) |
Manufacturers: Litton Systems Inc, Robert M Hadley Company Inc |
Are you looking for NSN 5950-01-331-3908 - Transformer Pulse parts? We can help! Simply complete the RFQ form given below to get started. The National Stock Number (NSN) is a 13-digit serial number assigned by the US Defense Logistics Agency (DLA) to items that are procured, stocked, and issued through the federal supply system. Parts under NSN 5950-01-331-3908 is 19294, 841289-0001 from manufacturer Robert M Hadley Company Inc, Litton Systems Inc. Use our optimized search engine to find your required part—then submit an instant RFQ for a quick, competitive quote. Here at Aviation Orbit, we make your purchasing process as simple and efficient as possible.
Part No | Manufacturer | Item Name | QTY | RFQ |
---|---|---|---|---|
19294 | Robert M Hadley Company Inc | transformer pulse | Avl | RFQ |
841289-0001 | Litton Systems Inc | transformer pulse | Avl | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABHP | OVERALL LENGTH | 0.600 INCHES MAXIMUM |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 0.400 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABMK | OVERALL WIDTH | 0.560 INCHES MAXIMUM |
ACZB | FREQUENCY RATING | 10.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
AEHZ | MAXIMUM OPERATING TEMP | 130.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AXGY | MOUNTING METHOD | TERMINAL SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 106.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
CRBZ | WINDING OPERATING CURRENT | 28.2 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 424.2 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.100 SINGLE COMPONENT 2ND SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.700 SINGLE COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 28.28 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 70.70 AC MILLIVOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
TEST | TEST DATA DOCUMENT | 13973-841289 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWI |
ADAU | BODY HEIGHT | 0.540 INCHES MAXIMUM |
CRGS | DC RESISTANCE RATING IN OHMS | 0.700 SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 2.82 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
TTQY | TERMINAL TYPE AND QUANTITY | 7 PIN |
5905-00-001-2971 (5905000012971) |
5905-00-001-3031 (5905000013031) |
5905-00-001-3050 (5905000013050) |
5905-00-001-3085 (5905000013085) |
5905-00-001-3197 (5905000013197) |
5905-00-001-3806 (5905000013806) |
5905-00-001-3819 (5905000013819) |
5905-00-001-3821 (5905000013821) |
5905-00-001-3822 (5905000013822) |
5905-00-001-3824 (5905000013824) |
5905-00-001-3825 (5905000013825) |
5905-00-001-3827 (5905000013827) |
We Hope You Choose Us as Your Low-Price, High-Quality Parts Distributor In the Future.
Request for Quote