NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-524-4718 Item Description: Circuit Breaker | 5925 | 015244718 | 0 | P | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Iagn-1-1-52-30.0 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | Body Style | SINGLE POLE TYPE |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 60.000 MAXIMUM AT 125 PCT SINGLE LOCATION AND 30.000 MAXIMUM AT 150 PCT SINGLE LOCATION AND 10.000 MAXIMUM AT 200 PCT SINGLE LOCATION AND 2.000 MAXIMUM AT 400 PCT SINGLE LOCATION AND 1.000 MAXIMUM AT 600 PCT SINGLE LOCATION AND 0.500 MAXIMUM AT 800 PCT SINGLE LOCATION AND 0.100 MAXIMUM AT 1000 PCT SINGLE LOCATION |
CPLM | Maximum Continuous Load Current Rating Per Pole | 30.0 AMPERES DC SINGLE LOCATION |
AKPX | Pole Quantity | 1 |
CPRH | Circuit Protection Type | OVERCURRENT SINGLE LOCATION |
CPRJ | Trip Release Method | MAGNETIC SINGLE LOCATION |
ADAT | Body Width | 0.750 INCHES NOMINAL |
CPRL | Trip Release Characteristic | TIME DELAY SINGLE LOCATION |
AXHR | Mounting Facility Type And Quantity | 2 THREADED HOLE |
MRC | Decoded Requirement | Clear Text Reply |
CPSM | Internal Trip Release Configuration | SHUNT TRIP SINGLE LOCATION |
ADAQ | Body Length | 2.256 INCHES MAXIMUM |
ADAU | Body Height | 2.000 INCHES NOMINAL |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 1.530 INCHES NOMINAL |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 80.0 DC SINGLE LOCATION |
CRTK | Switch Terminal Type | TAB W/SCREW |