Part Number : AP1-1-5-0-302
Manufacturer : Sensata Technologies Inc
NSN : 5925-00-967-6199 (5925009676199)
Alternate P/N : AP1150302
INC Code : 00136
NCB Code : 00
FSG : 59 Electrical and Electronic Equipment Components
NIIN : 00-967-6199 (009676199)
Country : USA
Submit your RFQ below for Sensata Technologies Inc Part AP1-1-5-0-302, a high-quality Circuit Breaker with NSN 5925009676199. Aviation Orbit provides a fast and reliable procurement solution for this part AP1-1-5-0-302, sourced directly from Sensata Technologies Inc (CAGE Code: 81541). The NSN 5925009676199 classifies this item under FSG 59 Electrical and Electronic Equipment Components and FSC 5925 Circuit Breakers, ensuring compliance with military and aviation standards.
For further identification, the NIIN 00-967-6199 confirms an NCB of 00 (origin: USA), while the INC 00136 provides additional classification details. Aviation Orbit streamlines the purchasing process, offering competitive pricing and dependable sourcing for Sensata Technologies Inc components. Submit your RFQ today for a quick response and seamless procurement experience.
MRC | Criteria | Characteristic |
---|---|---|
AAJE | THREAD PITCH DIAMETERS | +0.3503/+0.3537 INCHES |
AAQL | BODY STYLE | SINGLE POLE TYPE |
ABXD | BUSHING LENGTH | 0.360 INCHES MINIMUM AND 0.380 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 1.448 INCHES MINIMUM AND 1.510 INCHES MAXIMUM |
ADAT | BODY WIDTH | 0.567 INCHES MINIMUM AND 0.629 INCHES MAXIMUM |
ADTV | CASE MATERIAL | METAL |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.870 INCHES MINIMUM AND 0.880 INCHES MAXIMUM |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 1.524 INCHES MINIMUM AND 1.586 INCHES MAXIMUM |
AKPX | POLE QUANTITY | 1 |
APNQ | ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING W/PANEL SEAL |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CMLP | THREAD QUANTITY PER INCH | 32 |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 3.0 AMPERES DC SINGLE LOCATION |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 50.0 DC SINGLE LOCATION |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 500.0 DC SINGLE LOCATION |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATION |
CPRJ | TRIP RELEASE METHOD | MAGNETIC-HYDRAULIC SINGLE LOCATION |
CPRL | TRIP RELEASE CHARACTERISTIC | INSTANTANEOUS SINGLE LOCATION |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 115.0 SINGLE LOCATION |
CPRQ | RESET METHOD | MANUAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPRX | ACTUATOR POSITION DESIGNATION | AT POLE ONE |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP SINGLE LOCATION |
CQJX | NOMINAL THREAD SIZE | 0.375 INCHES |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | DUSTPROOF |
THSD | THREAD SERIES DESIGNATOR | UNEF |
TTQY | TERMINAL TYPE AND QUANTITY | 2 WIRE HOOK |
We Hope You Choose Us as Your Low-Price, High-Quality Parts Distributor In the Future.
Request for Quote