Alternate P/N : FK30702GB526630250MM
You can submit the RFQ form below for Part Number FK30.70(2)GB-526630-250MM, Valve Check by Manufacturer Naf Ab with NSN 4820014250362. Please ensure that all information is appropriately filled. These answers will help us offer you a better service.
Aviation Orbit, an ASAP Semiconductor company, is a leading distributor of Naf Ab and obsolete NSN parts such as FK30.70(2)GB-526630-250MM. We support defense/military, aerospace, commercial and industrial clients by supplying essential NSN parts at competitive prices.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
4820-01-425-0362 Item Description: Valve Check | 4820 | 014250362 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Fk30.70(2)gb-526630-250mm | 5 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
STYL | Style Designator | STRAIGHT THRU FLANGED ENDS |
CWCD | Nominal Outside Diameter | 315.0 MILLIMETERS ALL ENDS |
CWDF | Flange Face Design | PLAIN ALL ENDS |
MATT | Material | STEEL CORROSION RESISTING FLOW CONTROL DEVICE |
AWLS | Connection Type | FLANGE ALL ENDS |
MATT | Material | STEEL CORROSION RESISTING BODY |
MEDA | Media For Which Designed | LIQUID SINGLE RESPONSE |
BBJX | Mounting Position | HORIZONTAL OR VERTICAL |
AQLR | Valve Operation Method | AUTOMATIC |
AEHZ | Maximum Operating Temp | 450.0 DEG CELSIUS SINGLE RESPONSE |
CCFG | Valve Size | 114.0 MILLIMETERS |
CWCF | Face To Face Distance | 250.0 MILLIMETERS |
CQGM | Maximum Operating Pressure | 40.0 BAR SINGLE RESPONSE |
AGAV | End Item Identification | STRATEGIC SEALIFT CONVERSION SHIPS CLASS |
ADQU | Flow Control Device | DISK |
MDCL | Material Document And Classification | ASTM A351,GR CF-8M ASSN STD SINGLE MATERIAL RESPONSE BODY |
ARKN | Flange Shape | ROUND ALL ENDS |
ZZZY | Reference Number Differentiating Characteristics | AS DIFFERENTIATED BY EXTRA LONG REFERENCE NUMBER |
ADSU | Disk Loading Method | SPRING |
FEAT | Special Features | LIFTING RING; FLOW DIRECTION MUST BE UP WHEN USED IN VERTICAL POSITION; CAN BE USED WITH ANY LIQUID,GAS OR VAPOR THAT DOES NOT DAMAGE COMPONENT MATERIAL |
MRC | Decoded Requirement | Clear Text Reply |
We Hope You Choose Us as Your Low-Price, High-Quality Parts Distributor In the Future.
Request for Quote